 Model 

BH30

BH60B / BH60H

BS60H

BH100B / BH100H

LB100B

BH150B / BH150H

Cross Reference ALFA LAVAL

M3 

M6, M6M 

TS6M

M10M, M10B 

TL10B 

M15M, M15B

 Height, H [mm] 

480

920

940

704

704

1084

1084

1885

1923

1885

1885

Width, W [mm] 

180

320

330

400

410

470

470

480

480

610

650

 Min standard length, L [mm] 

400

500

500

530

540

700

700

850

850

1150

1150

 Max standard length, L [mm] 

650

1500

1500

1430

1440

2300

2300

2350

3250

2050

3250

Vertical port distance, VC [mm] 

357

640

640

380

380

719

719

1338

1338

1294

1294

 Horizontal port distance, HC [mm] 

60

140

140

203

203

225

225

225

225

298

298

 Max temperature [°C] 

180

180

180

180

180

180

180

160

160

180

180

 Max pressure [barg] 

16

10

16

16

20.6

10

16

10

16

10

16

 Flange size 

Pipe 1 1/4"

DN50/2" 

DN50/2" 

DN65/2"

DN65/2"

DN100/4"

DN100/4"

DN100/4"

DN100/4"

DN150/6"

DN150/6"

 Max. flow rate [kg/s] 

4

16

20

50

50

80

 Model 

BS200M /BS200B

BH200H

BH250

BH300H

Cross Reference ALFA LAVAL

TS20M

M20M,T20M,T20B

MX25B

M30

 Height, H [mm]

1405

2150

2595

2920

Width, W [mm]

740

750

920

1190

Min standard length, L [mm]

900

1250

1550

1650

Max standard length, L [mm]

2700

3350

3350

5200

Vertical port distance, VC [mm]

698

698

1939

1842

Horizontal port distance, HC [mm]

363

353

439

596

Max temperature

180

180

180

180

Max pressure [barg]

10/16

10/16

10/16

10/16

Flange size

DN200/8"

DN200/8"

DN200/DN250/8"/10"

DN300/DN350/12"/14"

Max. flow rate [kg/s]

190

225

250

497

How it works?

Gasket plate heat exchanger Standard design

The Gasket plate heat exchanger also called plate and frame plate heat exchanger consists of a pack of corrugated metal plates, The corrugation of the plates provides the passage between the plates, the two fluids transfer the heat between the channels. The plate pack is assembled between a fix frame plate and a movable pressure plate and compressed by tightening bolts. The gasket between the plates seals the inter plate channel and directs the fluids into alternate channels. The number of plates is determined by the design: the temperature program, flow rate,  pressure drop and physical properties of the fluids,. The plate corrugations promote fluid turbulence and the plate contact point support the plates against pressure. The frame plate and the pressure plate are fixed to a support column. Connections are located in the frame plate or pressure plates,this depends on the flow pass.

Advantages of the Baode Gasket Plate Heat Exchanger 
                                                           
*Less place & more efficient                                                                                                                                 
Baode  Gasket plate heat exchanger is compact size! With the compact  designs they just need 22–50% less space in the system than a comparable shell-and-tube heat exchanger. so they require up to 75% less cooling media, you just need a smaller pumps that will consume less energy.

*Six times more efficient than shell & tube  heat exchanger.

Compare with Shell-tube-heat exchanger, Baode gasket plate heat exchanger / Frame and plate heat exchanger offers up to six times greater heat transfer efficiency. The special corrugate plate pattern creates a high level of turbulence which, in combination with the low liquid volume and high heat transfer values. This make easy to control the heating or cooling effcient.

*Easy maintenance
When cleaning is needed, gasket plate heat exchanger can easily be opened, giving access to the plate surfaces, use pressure water or certain liquid to clean.

Working principle of gasekt plate heat exchanger

The channels in the heat exchanger are formed by the plates, the two media flow through alternate channels. The heat is transferred through the plate between the channels, the complete counter-current flow can make sure highest possible efficiency. The corrugation of the plates provides the passage between the plates, the contact point supports each plate against the adjacent one, this design can make the flow turbulence, which make the heat transfer effciecy

Frame of Gasket Plate Heat Exchanger

The Advanced Frame Structure

Rolling bearing system makes the installation and dismantling of the plate more convenient.

Stainless steel lining is our standard equipment.
 

Products
Brazed Plate Heat Exchanger
Gasket Plate Heat Exchanger
Gasket PHE Spares
Heating Insulation
PHE Application
PHE Application Other
PHE Application Solar
PHE Application
PHE Application General Industry
PHE Installation
Installation Manual





Trucking company tracking